The fs10a is a fast responding highly repeatable sensor which installs easily into a standard tube tee fitting or new sp76 nessi modular manifold.
Fci flow switch fs10a.
The fs10a is a universal flow switch and monitor specifically designed for gas and liquid process analyzer sampling systems.
The device in actual flow conditions is required i e actual switch point flow rate or flow close to intended value mode a or actual zero flow and full scale flow mode b.
Use of any w or codes requires prior approval from fci.
In both cases setting of the fail safe is also established and the final switch alarm point can be adjusted in 5 of span increments before exiting to normal operation.
To order an fs10a in an integral configuration please fill in each numbered block above by selecting required codes from the corresponding categories below.
Fs10a has a common 1 4 inch npt male connection for threading into standard tube tee fittings or fci s sp76 base.
In addition the fs10a utilizes proprietary equal mass sensing technolgoy from fci which is designed to achieve outstanding sensitivity and repeatability.
Also included standard is a 4 20ma output for flow rate trending or it can be assigned to temperature.
View and download fci fs10a installation operation manual online.
For special data documentation test reports or.
Flow switch flow monitor integral configuration instructions.
The fs10a is a fast responding highly repeatable sensor which installs easily into a standard tube tee fitting or sp76 nessi modular manifold.
The switch settings are user programmable for trip control of hysteresis and time delay.
Analyzer flow switch monitor.
The switch settings are user programmable for trip control of hysteresis and time delay.
For more information about the fs10a analyzer flow switch and monitor contact a cross flow and safety technologies expert.
Also included standard is a 4 20ma output for flow rate trending or it can be assigned to temperature.
The fs10a is a universal flow monitor and switch specifically designed for gas and liquid process analyzer sampling systems.
Changes in flow velocity directly affect the extent to which heat dissipates and in turn the magnitude of the temperature difference between the rtds.
Fs10a has a common 1 4 inch npt male connection for threading into standard tube tee fittings or fci s sp76 base.
Fci flow switches feature thermal dispersion technology in which the temperature difference is greatest in a no flow condition and decreases as flow increases cooling the heated rtd.